Watch our videos on this channel to learn the most advanced and skillful ways of diagnosing and repairing many types of Printed Circuit Boards (PCB). We use many types of advance tools to troubleshoot and fixing the problem. We also provide videos on Industrial, Commercial & Domestic Refrigeration Systems and Air Conditioning. Please Subscribe to our channel to stay updated and to keep learning. Thank you for Visiting our channel. Please don't forget to Subscribe, Share and like :) if you have any questions, please feel free to contact on +92 333 8921850
#code repair # inverter ac PCB course #review for ac repairing course #ACPCBrepairingcourse #AC PCB training institute #ACPCBrepairing #ac PCB repairing course in Pakistan #ac PCB repair #Repair ac #PCB #repair ac PCB repairing #BestACPCB repairing #ACrepairing course# best ac PCB repairing # inverter ac PCB repair and voltage study # ac PCB board repair # How to repair inverter ac PCB board # ac PCB repair Kaise kara# inverter ac PCB online course # inverter ac PCB repairing institute # inverter ac indoor PCB wiring # Haier washing machine PCB repair # online inverter repairing course# circuit repair training # inverter operation in power electronics #Basic electronics channel #inverter fridge PCB repair #washingmachinePCBrepaircourse# inverter circuit board #ac repairing training center #AC Godraj inverter AC #Ustad #Babar #BabarPCB #Babarelectronics #Haier inverter ac New model inverter PCB#DC inverter Haier outdoor PCB #Haier inverter ac old model inverter PCB# Haier indoor PCB # E1# E2# E3# E4# E5# E6# E7# E8# E9# EE# EH# F1# F2# F3# F4# F5# F6 #F7 #F8 #F9 #FO #FU #PO #P1 #P4 #P7#PH #H5 #OB #U8 #EE #EH #F1 #F21 #F24 #F25 #F28 #H5 #Samsung #E121 #E122 #E468 #E485 #Panasonicerror #H15 #H27 #H30 #Dawlance #C4 #mamunkanjan #electronics #inverter Washing machine PCB repair #Washing machine PCB Diagram #Gree Dc Dawlance PEL Orient Dc inverter ac P4 error code outdoor pcb Dc inverter ac PCB PEL #Dawlance Orient Kenwood #Changhong PEL Orient# Dawlance Kenwood Haier Dc inverter ac E7 error code outdoor pcb TCL DC inverter ac EE P4 P6 P8 error code Gree Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Changhong Ruba Dc inverter ac E5 error code VRF PCB repairing center Babar ElectronicsDawlance Dc inverter ac F1 error code outdoor pcb Dc inverter ac error code repair Sir BabarChanghong Ruba Dc inverter ac J5 error code Electrolux Dc inverter ac J5 error code outdoor pcb Dawlance Dc inverter ac P4 error code outdoor pcb Dc inverter ac service center sir Babar Kenwood Dc inverter ac FO error code outdoor pcb inverter ac pcb teacher Sir BabarHaier Dc inverter ac 1 ton /1.5 ton /2 ton PCB connection VRV / VRF PCB repairing center Sir BabarHaier Dc inverter ac compressor off in one minute No error IPM kya hai IPM Testing Sir Babar Gree DC inverter ac outdoor pcb E8 error code and indoor pcb Orient Dc inverter ac outdoor pcb P4 error
Transcript
00:00Assalamualaikum
00:02This is Orient's kit
00:04Check it, motor is on
00:06F4 has an error
00:08It will feel like a Camry but the speed is much faster
00:12This is an F4 error
00:14It has an Eltron kit
00:16Yes, it is getting an F4 error
00:18Now we will clarify what this error is
00:22But see the sensors that it has
00:24The sensors are also installed
00:26Everything is installed
00:28The error of the F4 is constantly coming
00:30Yes, but indoor
00:32Katic is fully on
00:34It is doing all the functions
00:36But what is the error of F4
00:42Look at this
00:44From here
00:46The wire is running here
00:48And this is the MD that is connected
00:50We will check the meter and connect the meter
00:52We put it on the base
00:54I put it here
00:56See it is dead
00:58Correct see this see this
01:00Let it be called dead
01:02Look it is dead
01:04Now we will change it on this mini
01:06When it is changed we will see that it was before
01:10Whether it has been removed or not is up to you
01:12The first one has also been changed
01:14The first one has also been changed
01:18Now we will change it again and see why
01:20There is an error in it or why it's all is gone
01:26What is this MD changing
01:28Now the lineage is enough
01:32Take it out
01:34So when we take out
01:36So when we take out
01:38The lineage
01:40Now we have changed this MD now
01:42Let's go
01:44Let's go
01:46You can see that it is a gridon
01:48If we do it with the help of bulk
02:02Then this compressor which is ours will turn on immediately
02:06Now let's see
02:08I turn it on again
02:10Turns on immediately I turned it off with the remote
02:12Now look
02:14It won't be long before we run it
02:16Because it's not open like this
02:18You don't have a headstone on it
02:20Look it's just open so it's a long time
02:22I also have a compressor
02:24This communication turns everything on
02:26You see this from the community
02:28I did it from here on
02:30See this app 4 error removed
02:32And immediately this is our compressor
02:34Look it's turned on
02:36But now we don't play it for long
02:38Because it's left open without the head sing
02:40So we're going to play it
02:42Our app 4 error was removed
02:44I would have turned it off
02:46I'm fine G
02:48The app 4 error is cleared
02:50Only one SMD was bad in it
02:52Which I changed
02:54If
02:56So this is clear
02:58Thanks for watching the video
03:08Just two
03:20We have checked the case
03:22As if
03:22Ilaubus
03:24We need a link
03:25Because
03:25Let's see
03:27This video
03:29Sounds back
03:30I'm keen onto all this
03:32And now that one