00:00Troubleshooting Load Sharing Problems in Synchronous Generators
00:03Synchronized generators can ensure a reliable and continuous supply of electrical energy.
00:10However, when multiple generators are involved, load sharing issues can arise.
00:15Today's presentation sheds light on some of them.
00:18Load sharing in synchronous generators explained.
00:21It simply means load sharing between generators running in parallel.
00:25In such settings, each generator is responsible for carrying a portion of the total load.
00:31If for some reason the load sharing becomes uneven, generators may become overloaded.
00:37Common Load Sharing Problems in Synchronous Generators
00:391. Unequal Load Distribution
00:42A common occurrence in parallel connected generators.
00:46A situation characterized by one generator becoming overloaded, disrupting the synchronization.
00:51Some of the prominent reasons why such a problem might emerge include
00:55Incorrect droop settings
00:57Variations in voltage setpoints
01:00Frequency mismatch
01:01Ensure that the droop settings are correctly calibrated, the frequency is synchronized across all units.
01:082. Poor Synchronization Between Generators
01:10Characterized by issues such as
01:13Generators fail to run in parallel-slash-disconnects from the system
01:17Large load swings when switching between generators
01:20Improperly aligned phase angle between generators
01:24Frequency mismatch
01:25Are some of the likely explanations
01:27Try to re-synchronize the generators
01:303. Incorrect Deadband on Governors
01:33Symptoms include
01:34Frequent generator trips
01:36Abnormal power fluctuations
01:38When load changes
01:39The reason behind erratic response to load changes could be
01:43An excessive wide governor deadband
01:45Consider adjusting the deadband to
01:48Improve load response time
01:50Reduce unnecessary trips
01:514. Incorrect governor settings
01:54Droop or speed regulation
01:56You might encounter issues such as
01:58Uneven load sharing or instability
02:00Fluctuating generator outputs
02:02You have not calibrated the droop settings appropriately
02:05Make sure that droop and speed settings are matched across all generators
02:095. Mechanical or electrical failures
02:13Generators are essentially mechanical devices designed to produce
02:17Electricity
02:18That's what they are
02:19As with any other machines
02:21They can malfunction due to component failure
02:24Check the component that you think has something to do with the generator failure
02:28Have it repaired or replaced
02:30To restore the generator's functionality
02:33So, there you have it
02:35A list of reasons why you might encounter load sharing problems in synchronous generators
02:39Things that you can do to fix it
02:42Seek professional help if necessary