Watch our videos on this channel to learn the most advanced and skillful ways of diagnosing and repairing many types of Printed Circuit Boards (PCB). We use many types of advance tools to troubleshoot and fixing the problem. We also provide videos on Industrial, Commercial & Domestic Refrigeration Systems and Air Conditioning. Please Subscribe to our channel to stay updated and to keep learning. Thank you for Visiting our channel. Please don't forget to Subscribe, Share and like :) if you have any questions, please feel free to contact on +92 333 8921850
#code repair # inverter ac PCB course #review for ac repairing course #ACPCBrepairingcourse #AC PCB training institute #ACPCBrepairing #ac PCB repairing course in Pakistan #ac PCB repair #Repair ac #PCB #repair ac PCB repairing #BestACPCB repairing #ACrepairing course# best ac PCB repairing # inverter ac PCB repair and voltage study # ac PCB board repair # How to repair inverter ac PCB board # ac PCB repair Kaise kara# inverter ac PCB online course # inverter ac PCB repairing institute # inverter ac indoor PCB wiring # Haier washing machine PCB repair # online inverter repairing course# circuit repair training # inverter operation in power electronics #Basic electronics channel #inverter fridge PCB repair #washingmachinePCBrepaircourse# inverter circuit board #ac repairing training center #AC Godraj inverter AC #Ustad #Babar #BabarPCB #Babarelectronics #Haier inverter ac New model inverter PCB#DC inverter Haier outdoor PCB #Haier inverter ac old model inverter PCB# Haier indoor PCB # E1# E2# E3# E4# E5# E6# E7# E8# E9# EE# EH# F1# F2# F3# F4# F5# F6 #F7 #F8 #F9 #FO #FU #PO #P1 #P4 #P7#PH #H5 #OB #U8 #EE #EH #F1 #F21 #F24 #F25 #F28 #H5 #Samsung #E121 #E122 #E468 #E485 #Panasonicerror #H15 #H27 #H30 #Dawlance #C4 #mamunkanjan #electronics #inverter Washing machine PCB repair #Washing machine PCB Diagram #Gree Dc Dawlance PEL Orient Dc inverter ac P4 error code outdoor pcb Dc inverter ac PCB PEL #Dawlance Orient Kenwood #Changhong PEL Orient# Dawlance Kenwood Haier Dc inverter ac E7 error code outdoor pcb TCL DC inverter ac EE P4 P6 P8 error code Gree Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Changhong Ruba Dc inverter ac E5 error code VRF PCB repairing center Babar ElectronicsDawlance Dc inverter ac F1 error code outdoor pcb Dc inverter ac error code repair Sir BabarChanghong Ruba Dc inverter ac J5 error code Electrolux Dc inverter ac J5 error code outdoor pcb Dawlance Dc inverter ac P4 error code outdoor pcb Dc inverter ac service center sir Babar Kenwood Dc inverter ac FO error code outdoor pcb inverter ac pcb teacher Sir BabarHaier Dc inverter ac 1 ton /1.5 ton /2 ton PCB connection VRV / VRF PCB repairing center Sir BabarHaier Dc inverter ac compressor off in one minute No error IPM kya hai IPM Testing Sir Babar Gree DC inverter ac outdoor pcb E8 error code and indoor pcb Orient Dc inverter ac outdoor pcb P4 error
Transcript
00:00As-Salaam-Alaikum, this kit came to us to be repaired. The problem is that it has an E6
00:21error of communication. See, this is the way to check it. I have turned it on. Now, I will
00:29turn it on remotely. I have set it to 16 temperature. If you are aware of the communication on this
00:36side, I will put this negative on neutral and I will put this wire on it. So, see, we are
00:43communicating on the meter in front. Okay, but this communication is happening in one
00:50way and not in one way. You can see it. Okay, and when it runs for a while, it gives an
00:57E6 error. This E6 error has come to us now. Now, we will repair it and see that it comes
01:09after a long time and the communication is still going on. Now, the E6 error has come
01:19to us. Now, we will repair it. The main problem is that the communication is still going on
01:28and the error also comes. This is a little complicated work. Now, we will repair it.
01:34This part of it has an auto coupler here for communication. This moment gets spoiled. First,
01:42we check the auto coupler. After the auto coupler, the whole system in this is that there are
01:50two auto couplers and two transistors. Now, let's see what is wrong and why this error
01:59comes. Let's see that the error comes and the communication is happening. Despite this,
02:06why does the communication error come?
02:36This is anode cathode. See here, there is a mark here. I am checking this. See here,
02:43I have checked it like this. Now, I will check this. But this auto coupler is not working.
03:01And this is that here, now I will test the rest of the things. They will be visible to us here.
03:07Show it there. See here, it is fine. This is our auto coupler with attached transistors.
03:16Let's check this. We see the transistors and I check all the SMDs that are attached to it.
03:21There is no fault in any of them so that we do not face this problem again that this error
03:28comes again. And see this. This transistor is attached. We check this. After this, SMDs
03:36are attached here. This is the transistor. This is attached to it. Let's see if there
03:41is anything else wrong in it. Yes, this is the SMD. This one is also fine. Check the meter
03:50and show it to them. After this, I also check this. This is also fine. And this is also fine.
03:59But only the rest of the transistors are fine. This is our auto coupler. See this is the
04:06auto coupler. It is on the low side from one side and this is the low side of it. This auto
04:11coupler is dead. Now I am going to change it. First of all, I will clean it properly.
04:20First of all, I will clean it properly. Then I will change it with the heat gun or the
04:26carburetor. Now we turn off the video. After this, I will change it and let you check
04:33whether E6 has gone in it or not, whether it has been removed or not. Now bring the heat
04:38gun. We will remove it with the heat gun. Turn on the heat gun.
04:49Now we have changed the auto coupler. Now we will see by turning it on again whether
04:55our error is over or not or what is the problem. See, now I have turned it on.
05:02Our temperature is set to 16. Now let's see. And we will run it for a while. Just wait
05:09because the heat sink is not installed on it. I will put it now and see. And it is on.
05:14So let's check whether our error is cleared or not. This motor is running. And let's see
05:21whether it turns on or not. This compressor is on. Let's see whether the compressor turns
05:26on or not or how it is now. It will take some time for the compressor to turn on. As soon
05:32as the compressor turns on, let's see that the error of E6 has not come yet. The error
05:37of E6 is expected that the compressor will start. And the communication is going on properly.
05:43See, this is the communication. This is its proper communication. See, this is the proper
05:49step. It is complete now. Let's see that now it turns on. That is, how long it turns on.
05:57If you like our video, then do like and share it. There is no expense for you in liking
06:03it. And neither is there any loss for you. But it gives us encouragement. Like it.
06:09Do subscribe to our channel. Do share it. But the video that we make for you is original
06:15and correct video so that you can work. If you have any problem, then you can repair
06:20the thing yourself.
06:24See, now our E6 error is over. This compressor is on. It is on. But see, I have not put
06:35any heat sink on it. And this is the analyzer. See, we also use it with us. See, because
06:42we know that it is 100% correct. It is open, so we will not use it for a long time. But
06:48see, it is on. Our kit is OK. Thank you for watching the video. Now subscribe to our
06:54channel. Like it. Share it. Thank you. The error of E6 has been solved. It is clear.
07:02See, now we see it with the help of the remote. I have turned it off. See, it is off.
07:08This is a big benefit of the analyzer. It tells us all the 6 IGBTs in it that none of them
07:16is bad. Thank you. Khuda Hafiz.