Dice Control: Unbalanced Dice Part 8 - Understanding The Dice Balancing Caliper

  • 11 years ago
Part 8 - Understanding The Dice Balancing Caliper. Also Consider -
BALANCING DICE FOR DUMMIES

While testing procedures to follow for dice in most State Gaming Commission Regulations is addressed, there are not any specific instructions or required training on how to actually conduct and use the tools that are stated in the Regulations. Some of the tools that are to be used could be relegated to an individuals common sense on how it should be used; however, after many years of observing casino employees conducting the inspection and testing of dice, it is clear that the majority do not know how to adequately conduct these tests, or do not take this requirement seriously. This is especially true, and most importantly, with respect to testing the dice for balance.

While the Balancing Caliper could be considered a crude tool and method to address if a dice cube is balanced, if used properly and the individual conducting the test knows how and what they are looking for, it can be effective.
The degree of imbalance in a die is variable, but if it can be determined that there is any imbalance in a die, it and the entire sleeve of matching serial numbers must be rejected for acceptance and use to comply with the balance requirements in the Regulatory Language.

1. The Balancing Caliper shall be placed on a solid flat level surface to conduct the tests. (ie. the table bank roll cover).

2. There are two methods that can be used to place the die into the cups of the Balancing Caliper. The first can
be used mostly for speed and ease in performing the general balance testing - the opposing corners of the die shall be placed in the cups of the Balancing Caliper while adjusting the cups to allow the opposing corners to rest loosely near the bottom of each cup and with the axis between the two opposing corners as level as possible. Proceed with the test as stated in #s3, 4 and 5 as follows, except when an imbalance is suspected.

If an imbalance is indicated or suspected while performing the test by the first method, the test shall proceed using the second method that differs only by more careful placement of the opposing corners as near to the center of the cup and careful adjustment of the cups to allow the die to rotate freely without slowing and effecting the spin rate, yet maintaining the axis between the opposing corners to remain as level as possible when conducting tests as stated in #s3, 4 and 5 as follows. This second method is more precise because the opposing corners are rotating and sitting on a more vertical surface of the Balancing Caliper's cups.

3. Spin the die and observe that it is spinning freely with the spin rate not being affected by the cups being too tight to effect a slower spin rate. This rate does not have to be fast, and an imbalance will show itself on how the spinning die comes to a stop.

A balanced die will come to a slow stop and will NOT reverse direction.

Steps 4. through 7. are continued below in the 1st Comment: